Flow nozzle meter
DP flowmeter for long-term stable flow measurement with reduced pressure loss
- Based on ISA 1932, long radius or Venturi nozzle (acc. to ISO 5167-3 or ASME MFC-3M)
- Accurate flow measurement at high flow velocities (e.g. feed water, steam, condensate, hydrocarbons, refined products, CO2, LH2)
- Manufacturing capability up to 48”; inhouse calibration also for applications with high Reynolds numbers
- Complete scope of supply from one source, incl. engineering, documentation, testing, calibration, valves, flow nozzle, process instrumentation, etc.
Flow nozzle meter
DP flowmeter for long-term stable flow measurement with reduced pressure loss
- Based on ISA 1932, long radius or Venturi nozzle (acc. to ISO 5167-3 or ASME MFC-3M)
- Accurate flow measurement at high flow velocities (e.g. feed water, steam, condensate, hydrocarbons, refined products, CO2, LH2)
- Manufacturing capability up to 48”; inhouse calibration also for applications with high Reynolds numbers
- Complete scope of supply from one source, incl. engineering, documentation, testing, calibration, valves, flow nozzle, process instrumentation, etc.
Overview
The flow nozzle meter is designed for accurate long-term stable flow measurement of liquids gases and steam, especially in high velocity applications with the risk of erosion or cavitation. Typical applications are feedwater, steam, condensate or refined products in various industries – from power plants, refineries to chemical processing facilities to oil and gas production or CCS.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Flowmeter assembly for high requirements of accuracy and long-term stability
- Short straight inlet/outlet pipe section requirements and low remaining pressure drop
- Manufacturing and calibration capabilities up to 48"
- Special 20-point calibration at high Reynolds-numbers possible (e.g. acc. to ASME PTC)
- Reduced TCO due to minimised need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
- Complete flowmeter solution with flow nozzle, DP transmitter, flow computer, valves, accessories, engineering, testing and documentation from one single source
- Redundancy available (1oo2, 2oo3)
- HART®7, Foundation fieldbus and Profibus-PA communication options
- SIL 2/3 certified versions
- Ex ia, Ex d approvals
- International references with renowned EPCs